Steam turbine powered feed water pump, CHP Plant Kutná Hora, Czechia

Steam turbine powered feed water pump, CHP Plant Kutná Hora, Czechia
Owner's Engineer Design and Studies Installation and Supply Diagnostics

We provided the designing and construction of steam turbine powered feed water pump. New technology was integrated into the existing technology. Its commissioning was done without the shutdown of the CHP plant.

BFS Industry activities:

  • Elaboration of feasibility study
  • Designing 
  • Supply and installation of the technology
  • Commissioning

“Brownfield” project

Construction: 09/2016 - 12/2016

Technical specifications of the turbine:

  • Steam turbine mechanical power: 120 kW
  • Inlet steam pressure: 4 MPa(g)
  • Outlet steam pressure: 0.12 MPa(g)
  • Inlet steam temperature: 400 °C